Applications
Handheld Laboratory Flow Meters
Portable gas flow meters make GC checks, calibrations and audits fast and easy. They fulfil a number of lab measuring functions all within the one device!
MB–Portable Gas Mass Flow Meters: Laboratory-grade flow verification, anywhere you need it
Alicat's portable flow flowmeters make calibration or validation simpler and faster by reducing downtime and disruption. Instant-on and real-time readings for multiple gases across wide flow ranges ensure periodic checks can be completed within just a few minutes. Flows can be calibrated with NIST-traceable accuracy for a variety of gases down to 1/200th of full scale or user-created gas compositions can be defined via COMPOSERTM.

- Available ranges: Max 0-5000 slpm, Min 0-0.5 sccm/0-500 sμlm
- Turndown ratio: 200:1 (standard gases) or 100:1 (corrosive gases)
- Standard accuracy calibration, NIST-traceable: +/- (0.8% of the reading + 0.2% of the full-scale range)
- Optional high-accuracy calibration, NIST-traceable: +/- (0.4% of the reading + 0.2% of the full-scale range)
Learn more about the MB Portable flow meter
MWB–Low Pressure Drop Portable Gas Mass Flow Meters: Measure flow with minimal system impact, anywhere you need it
"Whisper" series portable flow meters with low pressure drop are the perfect measuring and calibration instruments for mass and volumetric flow rates. Low pressure drop minimizes system impact, enabling flow measurement at near-atmospheric pressures or when there is little available system pressure.

- Available ranges: Max 0-1000 slpm, Min 0-0.5 sccm/0-500 sμlm
- Turndown ratio: 200:1 (standard gases) or 100:1 (corrosive gases)
- Standard accuracy calibration, NIST-traceable: +/- (0.8% of the reading + 0.2% of the full-scale range)
- Optional high-accuracy calibration, NIST-traceable: +/- (0.4% of the reading + 0.2% of the full-scale range)
Learn more about the MWB flow meter
AFS–Portable Gas Flow Calibrators: A portable gas flow standard that is ready for anything
When a calibration process requires the utmost accuracy, the AFS flow standard delivers. It features Alicat's most advanced calibration for optimal performance across changing temperatures, plus an on-board relative humidity sensor to maintain its accuracy all the way up to 100% RH (non-condensing). These advancements make possible a 0.75% of reading accuracy spec that requires no additional full-scale component. Low pressure drop allows calibration of volumetric flow rates with minimal impact. Averaged measurements and onboard data logging make it easy to gather multivariate flow data.

- Available ranges: Max 0-50 slpm, Min 0-5 sccm
- Turndown ratio: 200:1 when flowing air; 20:1 when flowing other gases or gas mixes
- Flow accuracy: +/- 0.75% of the reading (NIST-traceable)
- Typical measurement response time constant: 5-10 ms
- Warm-up time: No warm-up time required
- Compatible gases: 98 pre-loaded selectable gas calibrations; additional mixtures definable with COMPOSER
Related article
2H Offshore use Alicat portable mass flow meters for annulus integrity testing
Get in touch
If you would like to discuss your application please contact us.

Find this interesting, talk to us more about it
We aim to respond within 1 hour for customer enquiries

Call us
01953 609930
Email us
sales@pctflow.com