This month’s news article is an extract taken directly from the Alicat blog, “Alicats in the Wild” which highlights Graftel, LLC, in a common Alicat OEM application – leak testing – but one that is nestled within the highly demanding and rigorous world of nuclear regulation.

Founded in 1991 and headquartered in Elk Grove Village, Illinois, Graftel, LLC has emerged as the industry leader for nuclear facility leakage rate monitoring in the US. Regular monitoring both satisfies federal NRC regulations and serves as a preventative measure to help keep the working environment safe for power plant employees. From portable Local Leakage Rate Testers (LLRTs) to building-scale Integrated Leakage Rate Tests (ILRTs), Graftel is the preferred partner in testing for leakages at more than 90% of America’s nuclear power plants, as well as many others around the world.

Integrated Leak Rate Test (ILRT) Verification

The Nuclear Regulatory Commission (NRC) requires that all nuclear power plants undergo regular testing to ensure they comply with containment leakage requirements according to NRC 10 CFR 50 Appendix J. The requirements include three types of testing:

  • Type A tests measure the primary reactor containment overall integrated leakage rate
  • Type B tests detect local leaks measure leakage for primary reactor containment penetrations, including airlocks and electrical penetrations
  • Type C tests measure containment isolation valve leakage rates

Graftel invented their smart sensor technology for Type A integrated leakage rate tests (ILRTs) in 1993. Since then Graftel’s ILRT has become the primary system used in the United States. Smart sensors have made ILRTs more efficient by reducing both the time and the number of penetrations required to set up and conduct the tests. Not only does Graftel design and manufacture the smart sensors used in the ILRT, but they also calibrate them. After years of experience in calibrating their own instruments, Graftel established a top-notch calibration laboratory that is ISO 17025 certified and now services flow, pressure, temperature and humidity instrumentation.

The initial testing

During an ILRT, Graftel engineers pressurize the reactor building to 46 psig for a period of 8 hours. More than 50 Graftel smart sensors mounted inside the reactor return continuous temperature and humidity data to calculate pressure decay throughout the testing period. Following the conclusion of the primary test, the Graftel team performs a verification test. Using pressure taps in the building, the team induces a steady leak of about 50 slpm or so. During this test, Alicat mass flow meters monitor the actual leakage rate as the smart sensors continue to report their data. The two data sets are compared to verify that the smart sensors are operating within the required accuracy specifications. Graftel relies upon Alicat mass flow controllers for their measurement accuracy and insensitivity to changes in pressure and temperature during the 5-hour verification test.

The failure of the smallest components are sometimes the most devastating

Sometimes, the most devastating failures are caused by the smallest of components: valves, flanges, electrical penetrations. Having secured their position in Type A testing, Graftel began to design a portable leakage rate monitor that would be suitable for Type B and C testing in nuclear facilities. Today, Graftel’s Local Leakage Rate Test (LLRT) monitor (Model 9623-7) is a rugged, high-precision device capable of performing B and C testing via either flow make-up or pressure decay methods.

In a typical Type B test on a containment airlock, the airlock is sealed and pressurized to 50 psig. Air or nitrogen is supplied to the LLRT pressure regulator, which maintains the designated test pressure within the airlock. If the regulator allows additional flow into the airlock in order to maintain the test pressure, then this is evidence that leaks are present. The flow rate into the airlock reveals the degree of leakage out of the airlock. Every LLRT incorporates three Alicat mass flow meters to monitor high, medium and low flow ranges, depending upon the needs of the particular test. Whereas an airlock Type B test may require a high or medium range, a Type C test on an isolation valve may require the lowest flow range. Custom flow ranges may be ordered from Graftel as individual nuclear plant needs require them. Graftel also offers an LLRT version (Model 9623-7-ST4) that serves as a leakage rate monitoring standard with four Alicat mass flow meters inside.

Alicat’s mass flow meters were an easy choice

As OEM components for the LLRT, Alicat’s mass flow meters were an easy choice for Graftel. Alicat’s RS-232 communications protocol is standard on every mass flow meter and supports multi-drop natively. This allows easy integration of three Alicats with a single user interface designed by Graftel. The LLRT touch screen and Graftel programming allows users to directly access meter functions such as tare and gas select from a central interface. Since the LLRT is intended to be a rugged, portable unit, the mass flow meters inside it must also satisfy these conditions. With no moving parts or power-consuming heating elements, Alicat mass flow meters are energy-efficient and insensitive to bumps, vibrations or changes in orientation. Alicat’s recent impact test demonstrates the durability of these meters, as well as their ability to maintain accurate flow readings while being jolted by the impacter.

Some of Graftel’s earliest LLRTs have returned for maintenance still holding their original calibration accuracy after 11 years of use in the field. When radioactive contamination or other local plant conditions make annual recalibrations at the factory impossible, nuclear power plant engineers need to know they can still trust their leakage rate monitors. Together, Graftel and Alicat make that possible, and that allows everyone to rest more soundly at night.

For more information about Graftel, LLC, and nuclear power plant leakage rate monitoring, visit www.graftel.com