PCT

Premier Control Technologies

Flow, pressure, level and temperature solutions

01953 609930

VegaPuls Radar Continuous Level Measurement

The VegaPuls series of radar is a non-contacting level measurement for use in liquids and bulk solids under all process conditions. The level transmitters operate by emitting extremely short microwave impulses through the antenna system to the measured product. This is then reflected by the product surface and received again by the antenna system. The time from emission to reception of the signals is proportional to the level in the vessel. There are many measuring instruments available in the VegaPuls series and these are summarised below:

VegaPuls WL 61

Suitable for liquids in the water and sewage management industries with a measuring range of up to 15m with an accuracy of +/- 2mm. Process fittings available include threaded, mounting strap and compression flanges.
Process temperatures are from -40°c to + 80°c with process pressures from -1 to +2 bar.

VegaPuls 61

For liquids under easy or normal process conditions with a measuring range of up to 35 metres and an accuracy within + /- 2mm. Process connections available include threaded, mounting strap and compression flanges.
Process temperatures are from -40°c to + 80°c with process pressures from -1 to +3 bar.

VegaPuls 62

For use within storage tanks, reactors and process vessels and with arduous process conditions. Measuring ranges of up to 35 metres and an accuracy within + /- 2mm. Process connections available include 1 ½” BSP and NPT threaded, as well as flanges from DN50 / 2”.
Process temperatures are from -196°c to + 450°c with process pressures from -1 to +160 bar.

VegaPuls 63

Suitable for aggressive liquids or processes with hygienic requirements, measuring ranges of up to 35 metres and an accuracy within + /- 2mm. Process connections available include hygienic fittings, slotted nuts and flanges from DN50 / 2”.
Process temperatures are from -196°c to + 200°c with process pressures from -1 to +16 bar.

VegaPuls 64

The VegaPuls 64 sets new standards with 80 GHz level measurement, which is a first for radar level measurement for liquids! Suitable for all liquids or processes with hygienic requirements, measuring ranges of up to 30 metres and an accuracy within + /- 2mm. Process connections available include hygienic fittings, clamp, slotted nut, threaded connections and flanges from DN50 / 2”.
Process temperatures are from -40°c to + 200°c with process pressures from -1 to +20 bar.

VegaPuls 65

General liquid processes, with a measuring range of up to 35 metres with an accuracy of + / - 8mm. Process connections available include threaded 1 ½” BSP and NPT, flanges from DN 50 / 2” in size.
Process temperatures are from -40°c to + 150°c with process pressures from -1 to +16 bar.

VegaPuls 66

uitable for storage tanks or process vessels or standpipes under arduous process conditions with a measuring range of up to 35 metres with an accuracy of + / - 8mm.
Flanges are available from DN50 / 2”.
Process temperatures are from -60°c to + 400°c with process pressures from -1 to +160 bar.

VegaPuls 67

General bulk solids processes, with a measuring range of up to 15 metres with an accuracy of + / - 2mm. Process connections available include mounting strap or compression flanges from DN 80 / 3” in size.
Process temperatures are from -40°c to + 80°c with process pressures from -1 to +2 bar.

VegaPuls SR 68

Suitable for bulk solids under arduous process conditions, with a measuring range of up to 30 metres with an accuracy of + / - 2mm. Process connections available include threaded 1 ½” BSP and NPT, flanges from DN 50 / 2” in size.
Process temperatures are from -40°c to + 250°c with process pressures from -1 to +100 bar.

VegaPuls 68

Suitable for bulk solids also under arduous process conditions, with a measuring range of up to 75 metres with an accuracy of + / - 2mm. Process connections available include threaded 1 ½” BSP and NPT, flanges from DN 50 / 2” in size.
Process temperatures are from -196°c to + 450°c with process pressures from -1 to +160 bar.

VegaPuls 69

Suitable for bulk solids in higher or very narrow vessels, with a measuring range of up to 120 metres with an accuracy of + / - 5mm. Process connections available include mounting strap or compression flanges from DN 80 / 3” in size.
Process temperatures are from -40°c to + 200°c with process pressures from -1 to +3 bar.

Applications

  • Level measurement in liquids and bulk solids
  • Storage tanks, process vessels, standpipes
  • Aggressive liquids and arduous processes
  • Very high silos, large bunkers, segmented vessels
  • Stone crushers
  • Furnace
  • Reactors

Other features

  • Many Atex versions available including Ex ia and Ex d.
  • Ship Approvals
VegaPuls 62 Series Radar for Continuous level measurement of liquidsVegaPuls 63 Series Radar for Continuous level measurement of aggressive liquids or with hygienic requirements

Product enquiry