Premier Control Technologies Logo
Premier Control Technologies Fluid Solutions

Longer T100/T300/T600 - SC02 & SE02 OEM Peristaltic Pump

  • Wide flow rate range of 0.0063 ml/min - 3000ml/min
  • Extensive range of compatible pump heads: YZ15, YZ25, FG15, FG25, BZ, DMD and BPH01
  • Pump speed 0-600 rpm

The T100/T300/T600 Series SC02 and SE02 OEM pumps utilises a NEMA 23 stepper motor and an integrated driver. This OEM pump is well suited for applications in the Medical, Pharmaceutical and Analytical industries.

The OEM pump is compatable to numerous pump heads including the YZ15, YZ25, FG15, FG25, BZ, DMD and BPH01. This allows a wide range of different flow rates to be achieved, as many different tubing sizes (and materials) can be used - ranging from 0.0063 ml/min to 3000ml/min.

Dependant on the OEM pump, the Pump speed ranges from 0 - 600 rpm.

Mounting options include: Panel or Soleplate mounting.

RS485 interface, supporting both Modbus RTU protocol and Longer Pump OEM protocol.

Useful 'How to' videos

External Signal Control.

Communication Control.

DIP Switch Speed Setting.

Pump head and tubing compatibility

Pump HeadTubingsMax Flow Rate for Reference (mL/min)
Silicone TubingPharMed® TubingT100-SC02T300-SC02T600-SC02
YZ1515X, YZII15 (3 rollers)13#, 14#, 19#, 16#, 25#, 17#, 18#38011002200
YZ2515X15#, 24#Not Recommended2708001600
YZII2515#, 24#, 35#, 36#Not Recommended50015003000
FG15-1313#, 14#, 19#, 16#, 25#, 17#, 18#13#, 14#, 19#, 16#43012002400
FG25-1315#, 24#Not Recommended32011002200
DMD15-13-B2x13#, 2x14#, 2x19#, 2x16#, 2x25#2x13#, 2x14#, 2x19#, 2x16#37510352070
DMD15-13-D37510352070
BZ15-13-A14#2275150
BZ15-13-B16#80230460
BZ15-14-C25#150480960
BZ15-14-D17#2708001600
BZ25-13-B24#Not Recommended2508001600
DG15-2416#, 25#, 17#Not Recommended300 (single channel)900 (single channel)1800 (single channel)
DG15-2813#, 14#, ID≤3.17mm, Wall Thickness: 1mmNot Recommended75 (single channel)Not RecommendedNot Recommended
DG-1, DG-2 (6 rollers)ID≤3.17mm, Wall Thickness 0.8–1mm48 (single channel)Not RecommendedNot Recommended
DG-4, DG-6, DG-8 (6 rollers)ID≤3.17mm, Wall Thickness 0.8–1mmNot Recommended48 (single channel)Not RecommendedNot Recommended
DG-1, DG-2 (10 rollers)ID≤3.17mm, Wall Thickness 0.8–1mm32 (single channel)Not RecommendedNot Recommended
DG-4 (10 rollers)ID≤3.17mm, Wall Thickness 0.8–1mmNot Recommended32 (single channel)Not RecommendedNot Recommended
BPH0113#, 14#, 19#, 16#, 25#82260530

Model numbers

  • T100-SE02-01
  • T100-SC02-01
  • T300-SE02-01
  • T300-SC02-01
  • T600-SE02-01
  • T600-SC02-01

Industries

The Longer T100/T300/T600 - SC02 & SE02 OEM Peristaltic Pump is widely used in the following industries:

Manufacturer

Longer Precision Pump